Citation: | WANG Wei-min, JIN Liu-yu, XU Fu-xing, DING Chuan-fan. Effect of Amplitude-Scanning ac on the Performance of Ion Trap Mass Spectrometry[J]. Journal of Chinese Mass Spectrometry Society, 2021, 42(5): 942-950. DOI: 10.7538/zpxb.2021.0129 |
[1] |
PAUL W, OSBERGHAUS O, FISCHER E. Forschungsberichte des wirtchaft und verkehrministeriums nordrhein westfalen[J]. Westdeutscher Verlag, Kln and Opladen, 1958: 415.
|
[2] |
DAWSON P H, WHETTEN N R. Ion storage in threedimensional, rotationally symmetric, quadrupole fields. I. Theoretical treatment[J]. Journal of Vacuum Science&Technology, 1968, 5: 1-10.
|
[3] |
MARCH R E, TODD J F. Quadrupole ion trap mass spectrometry[M]. John Wiley & Sons: 2005: 165.
|
[4] |
MARCH R E, TODD J F. Practical aspects of trapped ion mass spectrometry, volume Ⅳ: theory and instrumentation[M]. CRC Press, 2010.
|
[5] |
HENDRICKS P, DUNCAN J, NOLL R J, OUYANG Z, COOKS R G. Performance of a low voltage ion trap[J]. International Journal of Mass Spectrometry, 2011, 305(1): 69-73.
|
[6] |
TAYLOR N, AUSTIN D E. A simplified toroidal ion trap mass analyzer[J]. International Journal of Mass Spectrometry, 2012, 321: 25-32.
|
[7] |
SCHWARTZ J C, SENKO M W, SYKA J E. A twodimensional quadrupole ion trap mass spectrometer[J]. Journal of the American Society for Mass Spectrometry, 2002, 13(6): 659-669.
|
[8] |
DANG Q, XU F, XIE X, XU C, DING C F. Enhancement of ion activation and collisioninduced dissociation by simultaneous dipolar excitation of ions in X- and Y-directions in a linear ion trap[J]. Analytical Chemistry, 2015, 87(11): 5561-5568.
|
[9] |
LI X, JIANG G, LUO C, XU F, DING C F. Ion trap array mass analyzer: structure and performance[J]. Analytical Chemistry, 2009, 81(12): 4840-4846.
|
[10] |
JONSCHER K R, YATES J R. The quadrupole ion trap mass spectrometera small solution to a big challenge[J]. Analytical Biochemistry, 1997, 244(1): 1-15.
|
[11] |
WANG Y, DING C F, XU F, KONENKOV N V, DING H. Linear ion trap mass selectivity with impulse power supply and sinusoidal dipolar excitation[J]. Rapid Communications in Mass Spectrometry, 2016, 30: 2664-2670.
|
[12] |
JIANG T, XU Q, ZHANG H, LI D, XU W. Improving the performances of a “brick mass spectrometer” by quadrupole enhanced dipolar resonance ejection from the linear ion trap[J]. Analytical Chemistry, 2018, 90(19): 11671-11679.
|
[13] |
SNYDER D T, PULLIAM C J, WILEY J S, DUNCAN J, COOKS R G. Experimental characterization of secular frequency scanning in ion trap mass spectrometers[J]. Journal of The American Society for Mass Spectrometry, 2016, 27(7): 1243-1255.
|
[14] |
SCHWARTZ J C, SYKA J E, JARDINE I. High resolution on a quadrupole ion trap mass spectrometer[J]. Journal of the American Society for Mass Spectrometry, 1991, 2(3): 198-204.
|
[15] |
MOXOM J, REILLY P T, WHITTEN W B, RAMSEY J M. Double resonance ejection in a micro ion trap mass spectrometer[J]. Rapid Communications in Mass Spectrometry, 2002, 16(8): 755-760.
|
[16] |
WILLIAMS J D, COX K A, COOKS R G, McLUCKEY S A, HART K J, GOERINGER D E. Resonance ejection ion trap mass spectrometry and nonlinear field contributions: the effect of scan direction on mass resolution[J]. Analytical Chemistry, 1994, 66(5): 725-729.
|
[17] |
XU F, WANG W, JIN L, QIAN B, DING C F. Measurement of the effective electric field radius on digital ion trap spectrometer[J]. Analyst, 2021, 146: 3810-3817.
|
[18] |
ZHANG Z Y, YUAN G Z, HE Y, QIAN J, ZHANG S G, YAO R J, DING C F, LI X X. Research of unidirectional ion ejection in printed-circuit-board ion trap[J]. Chinese Journal of Analytical Chemistry, 2017, 45(2): 297-302.
|
1. |
裴泓明,刘梅英,徐赫奕,张谛,谢洁,屈子裕,黄泽建,蒋长元,蒙颖艳,戴新华,方向,王庆辉,江游. 离子阱质谱仪质量分段校正算法研究. 质谱学报. 2023(05): 676-684 .
![]() |