PEI Hong-ming, LIU Mei-ying, XU He-yi, ZHANG Di, XIE Jie, QU Zi-yu, HUANG Ze-jian, JIANG Chang-yuan, MENG Ying-yan, DAI Xin-hua, FANG Xiang, WANG Qing-hui, JIANG You. Study on Mass Calibration Segmentation Algorithm of Ion Trap Mass Spectrometer[J]. Journal of Chinese Mass Spectrometry Society, 2023, 44(5): 676-684. DOI: 10.7538/zpxb.2022.0178
Citation: PEI Hong-ming, LIU Mei-ying, XU He-yi, ZHANG Di, XIE Jie, QU Zi-yu, HUANG Ze-jian, JIANG Chang-yuan, MENG Ying-yan, DAI Xin-hua, FANG Xiang, WANG Qing-hui, JIANG You. Study on Mass Calibration Segmentation Algorithm of Ion Trap Mass Spectrometer[J]. Journal of Chinese Mass Spectrometry Society, 2023, 44(5): 676-684. DOI: 10.7538/zpxb.2022.0178

Study on Mass Calibration Segmentation Algorithm of Ion Trap Mass Spectrometer

More Information
  • In order to ensure the measurement accuracy of ion trap mass spectrometer, it is necessary to perform mass calibration on the instrument when there is a mass shift. Mass calibration can be achieved by improving the stability of the electrical components or upgrading the hardware with significant technical costs. Compared with hardware optimization, mass calibration based on software algorithms can better utilize the performance of existing instruments. Mass calibration can be achieved by manually inputting standard samples or calibration solution parameters. However, mass axis calibration in this way still requires setting specific segmentation points based on the actual situation and manually adjusting them to achieve the desired accuracy. Therefore, to improve the low efficiency with manual segmentation during mass calibration, an automatic segmented calibration algorithm was proposed to improve the calibration accuracy and facilitate rapid operation. The algorithm used point by point fitting to determine whether the segment interval met the requirements and also determined each segment interval. At the same time, the mass axis was automatically segmented to reduce the mass deviation of each checkpoint. This method was compared with traditional method, different deviation thresholds were explored, and multiple instruments were selected to verify this method. The results showed that the algorithm can reasonably segment the mass axis and establish a new linear relationship between electrical parameters and m/z under existing conditions, allowing the deviation of each checkpoint to be controlled within a lower preset range (±01 u), thus improving the instrument's calibration efficiency and measurement accuracy, reducing the difficulty of personnel operation. The significance of this study is that the algorithm only adjusts and optimizes the signals generated by the hardware without changing the structure of the instrument itself, which is helpful for improving the overall performance and stability of the instrument. Moreover, the principle and conclusion of the algorithm are independent of the experimental platform, so it can be applied to a variety of other types of mass spectrometers. For the insufficient points, firstly, the upper limit of accuracy provided by the algorithm itself is still determined by the hardware accuracy of the instrument, so it is only possible to calibrate and optimize the mass axis within a certain accuracy range. Secondly, because the calibration process requires a certain number of reference points, which poses certain requirements for the selection of calibration solutions.
  • [1]
    汪曣,刘海培,孙传强,韩文念,贾明正,蒋学慧. 液相色谱-三重四极杆质谱定量分析算法[J]. 天津大学学报(自然科学与工程技术版),2020,53(6):617-625.
    WANG Yan, LIU Haipei, SUN Chuanqiang, HAN Wennian, JIA Mingzheng, JIANG Xuehui. Quantitative analysis algorithm of liquid chromatography-triple quadrupole mass spectrometry[J]. Journal of Tianjin University (Science and Technology), 2020, 53(6): 617-625(in Chinese).
    [2]
    周义. 质谱数据处理算法的研究与应用设计[D]. 宁波:宁波大学,2017.
    [3]
    DOROSHENKO V M, COTTER R J, LUBMAN D M. Linear mass calibration in the quadrupole ion-trap mass spectrometer[J]. Rapid Communications in Mass Spectrometry, 1994, 8(9): 766-776.
    [4]
    SCHWARTZ J C, REMES P M. Methods and apparatus for calibrating ion trap mass spectrometers: United States, EP2587520[P]. 2013-05-01.
    [5]
    陈焕文,李明,费强,金钦汉. 小型离子阱的质量校正[J]. 分析化学,2005(10):1505-1508.
    CHEN Huanwen, LI Ming, FEI Qiang, JIN Qinhan. Mass calibration of miniaturized ion trap[J]. Chinese Journal of Analytical Chemistry, 2005(10): 1505-1508(in Chinese).
    [6]
    YASUAKI T, TAKAYUKI N, MINORU S, YUICHIRO H. Method for mass calibration: United States, 6194716[P]. 2001-02-27.
    [7]
    罗婵. 四极场质量分析器的理论研究[D]. 上海:复旦大学,2011.
    [8]
    王伟民,靳留雨,徐福兴,丁传凡. 理论模拟和实验对照研究幅值扫描ac对离子阱质谱性能的影响[J]. 质谱学报,2021,42(5):942-950.
    WANG Weimin, JIN Liuyu, XU Fuxing, DING Chuanfan. Effect of amplitude-scanning ac on the performance of ion trap mass spectrometry[J]. Journal of Chinese Mass Spectrometry Society, 2021, 42(5): 942-950(in Chinese).
    [9]
    MOXOM J, REILLY P T A, WHITTEN W B, RAMSEY J M. Double resonance ejection in a micro ion trap mass spectrometer[J]. Rapid Communications in Mass Spectrometry, 2002, 16(8): 755-760.
    [10]
    邓勃. 关于校正曲线建立和应用中一些问题的探讨[J]. 中国无机分析化学,2011,1(3):1-7.
    DENG Bo. The discussion on some problems with construction and application of calibration curve[J]. Chinese Journal of Inorganic Analytical Chemistry, 2011, 1(3): 1-7(in Chinese).
    [11]
    刘磊,江游,刘梅英,戴新华,方向,陈大舟,邱春玲,黄泽建. 四极杆质谱质量分辨自动调节技术研究[J]. 质谱学报,2020,41(2):118-124.
    LIU Lei, JIANG You, LIU Meiying, DAI Xinhua, FANG Xiang, CHEN Dazhou, QIU Chunling, HUANG Zejian. Research on automatic adjustment of mass resolution in quadrupole mass spectrometry[J]. Journal of Chinese Mass Spectrometry Society, 2020, 41(2): 118-124(in Chinese).
    [12]
    谢洁,易可可,高文静,刘浩,李家练,黄泽建,刘梅英,余青霓,王涵文,江游,戴新华,方向. 基于四极杆-线形离子阱串联质谱技术测量血清25OHD[J]. 质谱学报,2023,44(1):13-24.
    XIE Jie, YI Keke, GAO Wenjing, LIU Hao, LI Jialian, HUANG Zejian, LIU Meiying, YU Qingni, WANG Hanwen, JIANG You, DAI Xinhua, FANG Xiang. Determination of 25OHD in serum based on quadrupole-linear ion tandem mass spectrometric technique[J]. Journal of Chinese Mass Spectrometry Society, 2023, 44(1): 13-24(in Chinese).
    [13]
    李畅. 高灵敏度四极杆-线形离子阱串联质谱技术研究[D]. 长春:吉林大学,2022.
    [14]
    SCHWARTZ C J, SENKO W M, SYKA E J. A two-dimensional quadrupole ion trap mass spectrometer[J]. Journal of the American Society for Mass Spectrometry, 2002, 13(6): 659-669.
    [15]
    COLLINGS B A. Fragmentation of ions in a low pressure linear ion trap[J]. Journal of the American Society for Mass Spectrometry, 2007, 18(8): 1459-1466.

Catalog

    Article views (320) PDF downloads (245) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return