Separation and Characterization of 4 Related Impurities in Puerarin Bulk Drug by HPLC-UV-FTICRMS/MSn
-
-
Abstract
The molecular structures and mechanism for the fragmentations of the related impurities were proposed by the MSn and HRMS results obtained by high performance liquid chromatography-ultraviolet detector-fourier transform ion cyclotron resonace mass spectrometry(HPLC-UV-FTICRMS/MSn). The molecular compositions of the related impurities and some of the fragmentations were confirmed by the HRMS datas. Four related impurities in puerarin bulk drug were separated. Their M+H+ ion peaks are m/z 433.112 95, 433.112 92, 417.118 01 and 417.118 01, respectively. They are identified as 3’-hydoxypuerarin, genistin-8-C-glucoside, neopuerarin B and neopuerarin A on the basis of fragmentation mechanism and reference data.
-
-