HAO Guang-tao, LI Yuan-yuan, HE Shi-xue, CHEN Gang, GAO Hong-zhi, LIU Ze-yuan. Quantitative Determination of Entecavir in Human Plasma by HPLC-MS/MS[J]. Journal of Chinese Mass Spectrometry Society, 2010, 31(4): 252-256.
Citation: HAO Guang-tao, LI Yuan-yuan, HE Shi-xue, CHEN Gang, GAO Hong-zhi, LIU Ze-yuan. Quantitative Determination of Entecavir in Human Plasma by HPLC-MS/MS[J]. Journal of Chinese Mass Spectrometry Society, 2010, 31(4): 252-256.

Quantitative Determination of Entecavir in Human Plasma by HPLC-MS/MS

  • Entecavir in human plasma was determined by high performance liquid coupled with-tandem mass spectrometry (HPLC-MS/MS). Diazepam was used as internal standard. Entecavir was separated on a Waters-Eterra MS-C18 column(2.1×50 mm×5 μm). Electrospray ionization(ESI) source was applied, and multiple reaction monitoring(MRM) mode was operated in the positive mode with the monitor ions at m/z 278.2→152.1 for entecavir and m/z 285.0→193.0 for the internal standard, respectively. The linear calibration curve is obtained over the concentration range of 0.05—20 μg•L-1. The limit of quantitation is 0.05 μg•L-1(n=6). The inter and intra-day precision(RSD) is less than 15%. The average recoveries are above 75%.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return