Determination of Estriol in Human Urine by GC/MSD[J]. Journal of Chinese Mass Spectrometry Society, 2001, 22(3): 47-47.
Citation: Determination of Estriol in Human Urine by GC/MSD[J]. Journal of Chinese Mass Spectrometry Society, 2001, 22(3): 47-47.

Determination of Estriol in Human Urine by GC/MSD

  • Estriol (E 3) was qualitatively and quantitatively determined by GC/MSD with an internal standard, 3-cyclopentanoxy-estrone (CE 1). Urine sample was hydrolyzed with hydrochloric aid and then extracted with ether. Finally it was derived with acetic anhydride and pyridine. The method was used in determination of the urine of 2 patients who were suffered from radiation accidents and then treated with E 3. The results showed that E 3(OAc) 3 was excreted as its prototype and the excretion was mainly excreted during first three days.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return