HUANG Ze-jian, JIANG You, XIONG Xing-chuang, ZHANG Xiao-hua, FANG Xiang. Design and Test of Portable Mass Spectrometer Based on Step-Like Electrode Linear Ion Trap[J]. Journal of Chinese Mass Spectrometry Society, 2011, 32(2): 104-107.
Citation: HUANG Ze-jian, JIANG You, XIONG Xing-chuang, ZHANG Xiao-hua, FANG Xiang. Design and Test of Portable Mass Spectrometer Based on Step-Like Electrode Linear Ion Trap[J]. Journal of Chinese Mass Spectrometry Society, 2011, 32(2): 104-107.

Design and Test of Portable Mass Spectrometer Based on Step-Like Electrode Linear Ion Trap

More Information
  • Received Date: December 31, 1899
  • Revised Date: December 31, 1899
  • The structure and application testing of a home-made portable mass spectrometer based on step-like electrode linear ion trap was introduced. The analyzer is step-like electrode linear ion trap, and the ion source is glow discharge electron impact ionization (GDEI) source and dielectric barrier discharge ionization (DBDI) source. The device is 10 kg weight,consuming less than 100 W, 33 cm in length, 20 cm in width and 20 cm in height, which can detect gas, solid and liquid. Volatile organic gases injected in the vacuum chamber from the membrane inlet interface, and ionized by GDEI. A discontinuous atmospheric pressure interface was assembled, with which atmospheric pressure ionization source was selected. By a DBDI source, the DDU and compound aminopyrine tablets was detected successfully and quickly.
  • [1]
    CORNISH T J, ANTOINE M D, ECELBERGER S A, et al. Arrayed time-of-flight mass spectrometry for time-critical detection of hazardous agents[J]. Anal Chem, 2005, 77(13): 3 954-3 959.
    [2]
    SHORTT B J, DARRACH M R, HOLLAND P M, et al. Miniaturized system of a gas chromatograph coupled with a Paul ion trap mass spectrometer[J]. J Mass Spectrom, 2005, 40(1): 36-42.
    [3]
    OUYANG Z, WU G, SONG Y, et al. Rectilinear ion trap: Concepts, calculations, and analytical performance of a new mass analyzer[J]. Anal Chem, 2004, 76(16): 4 595-4 605.
    [4]
    GAO L, SONG Q, PATTERSON G E, et al. Handheld rectilinear ion trap mass spectrometer[J]. Anal Chem, 2006, 78(17): 5 994-6 002.
    [5]
    BOUMSELLEK S, FERRAN R J. Trade-offs in miniature quadrupole designs[J]. J Am Soc Mass Spectrom, 2001, 12(6): 633-640.
    [6]
    JANFELT C, FRANDSEN H, LAURITSEN F R. Characterization of a mini membrane inlet mass spectrometer for on-site detection of contaminants in both aqueous and liquid organic samples[J]. Rapid Commun Mass Spectrom, 2006, 20(9): 1 441-1 446.
    [7]
    LAMMERT S A, ROCKWOOD A A, WANG M, et al. Miniature toroidal radio frequency ion trap mass analyzer[J]. J Am Soc Mass Spectrom, 2006, 17(7): 916-922.
    [8]
    SPARKMAN O D. Mass spectrometry PittCon 2007[J]. J Am Soc Mass Spectrom, 2007,18(6): 1 146-1 159.
    [9]
    GAO L, SUGIARTO A, HARPER J D, et al. Design and characterization of a multisource Hand-Held tandem mass spectrometer[J]. Anal Chem, 2008, 80(19): 7 198-7 205.
    [10]
    FANG X. Ion trap, multiple-electrode pole system and electrode pole for mass spectrometic analysis: RU, 2368980[P]. 2009-09-27.
    [11]
    NA N, ZHAO M, ZHANG S, et al. Development of a dielectric barrier discharge ion source for ambient mass spectrometry[J]. J Am Soc Mass Spectrom, 2007,18(10): 1 859-1 862.
    [12]
    GAO L, SONG Q, NOLL R J, et al. Glow discharge electron impact ionization source for miniature mass spectrometers[J]. J Mass Spectrom, 2007,42(5): 675-680.
    [13]
    KEIL A, HERNANDEZ-SOTO H, NOLL R J, et al. Monitoring of toxic compounds in air using a handheld rectilinear ion trap mass spectrometer[J]. Anal Chem, 2008,80(3): 734-741.
    [14]
    NA N, ZHANG C, ZHAO M, et al. Direct detection of explosives on solid surfaces by mass spectrometry with an ambient ion source based on dielectric barrier discharge[J]. J Mass Spectrom, 2007,42(8): 1 079-1 085.
    [15]
    ZHANG Y, MA X, ZHANG S, et al. Direct detection of explosives on solid surfaces by low temperature plasma desorption mass spectrometry[J]. Analyst, 2009,134(1): 176-181.
    [16]
    NA N, XIA Y, ZHOU Z, et al. Birch reduction of benzene in a low-temperature plasma[J]. Angew Chem Int Ed, 2009,48: 2 017-2 019.
    [17]
    LIU Y, LIN Z, ZHANG S, et al. Rapid screening of active ingredients in drugs by mass spectrometry with low-temperature plasma probe[J]. Anal Bioanal Chem, 2009,395(3): 591-599.
    [18]
    MA X, ZHAO M, LIN Z, et al. Versatile platform employing desorption electrospray ionization mass spectrometry for high-throughput analysis[J]. Anal Chem, 2008, 80(15): 6 131-6 136.