同位素稀释-液相色谱-串联质谱法同时测定水产品中雌激素、孕激素和雄激素

Simultaneous Determination of the Estrogen, Progestogen and Androgen in Aquatic Products by Isotope Dilution LC-MS/MS

  • 摘要: 建立了液相色谱-串联质谱(LC-MS/MS)同时测定水产品中雌激素、孕激素和雄激素的方法。样品用甲基叔丁基醚和乙酸乙酯提取,C18固相萃取柱净化,甲醇洗脱,以0.02%氨水-甲醇为流动相,XBridge RP-18色谱柱分离后,在LC-MS/MS多反应监测模式下进行定性与定量分析。其中孕激素、雄激素和苯甲酸雌二醇采用正离子扫描;雌激素采用负离子扫描,内标法定量。方法检出限为0.5~2 μg/kg(S/N≥3)。27种激素在2 μg/kg和10 μg/kg添加水平下,相对标准偏差分别为5.3%~15%和2.3%~8.2%,平均回收率分别为73.0%~120%和79.0%~108%。该方法灵敏度高、操作简单,适用于水产品中27种性激素的定量与确证分析。

     

    Abstract: A method of liquid chromatography-tandem mass spectrometry(LC-MS/MS) was developed for the simultaneous determination of estrogen, progestogen and androgen in aquatic products muscle tissues. The sample were extracted by tert-butyl methyl ether and ethyl acetate, purified on C18 solid phase extraction column, eluted by methanol. After XBridge RP-18 column separation using 0.02% ammonia-methanol as mobile phase, the eluents were qualitatively and quantitatively determined under multi-reaction monitoring scan type with tandem mass analyzer using positive polarity mode for the progestogen, androgen and estradiol benzoate, negative polarity for the estrogen respectively, the quantification was performed with internal standard method. The limit of detection is 0.5—2 μg/kg(S/N≥3). Spike recoveries are 73.0%—120% and 79.0%—108% in 2 μg/kg and 10 μg/kg with relative standard deviation of 5.3%—15% and 2.3%—8.2%. The method is effective, simple and sensitive, and suitable for the determination and confirmation of 27 kinds of sex hormones in aquatic products.

     

/