基于快速蒸发离子化质谱实时检测空气油炸鲳鱼的脂质组学轮廓

Real-time Assessing the Lipidomics Profile of Pomfret (Pampus argenteus) During Air-frying by Rapid Evaporative Ionization Mass Spectrometry

  • 摘要: 快速蒸发离子化质谱(rapid evaporative ionization mass spectrometry, REIMS)是一种无需样品预处理的新型质谱技术,通过手持智能手术刀切割样品采集数据从而获得脂质组学轮廓。本研究采用REIMS技术和主成分分析(principal component analysis, PCA)、隐结构正交投影(orthogonal projection to latent structure, OPLS)等数理统计方法实时监测鲳鱼在空气油炸过程中脂质组学轮廓变化,并探究不同空气油炸温度对鲳鱼肌肉组织脂质组成的影响。通过单因素条件优化得到适宜的REIMS系统参数,电刀输出功率20 W、电刀切割功率1 mm/s、辅助溶剂流速100 μL/min,从而获得稳定可靠的质谱轮廓图。在PCA分析的基础上进行OPLS分析,得到10个重要的特征离子(VIP>1),其中PE(O-16∶1/22∶6)只在原料中检测到,为4.61%;此外,PE(22∶5/22∶6)在10个磷脂离子中的不饱和度最高,其相对含量随油炸温度的升高而降低,同样可见于PA(18∶1/22∶6)和PI(18∶0/22∶6),说明磷脂的饱和度有随油炸温度升高而上升的趋势。经方法验证显示,REIMS检测离子的信噪比范围为49.58~205.30,日内和日间精密度的相对标准偏差为3.10%~7.28%,灵敏度和精密度均较高,因此,该方法将成为脂质组学研究过程中一种简单、高效、准确的新型技术手段。

     

    Abstract: Rapid evaporative ionization mass spectrometry (REIMS) is a novel mass spectrometry technology that does not require any sample pretreatment. Mass spectrum could be easily acquired by a hand-held intelligent knife coupling to REIMS to obtain the lipidomics profile. In this study, REIMS, principal component analysis (PCA), and orthogonal projection to latent structure (OPLS) were used to real-time assessing the lipidomics profiles of pomfret (Pampus argenteus) during air-frying and explore the effect of different air-frying temperatures on the lipid composition of pomfret muscle tissue. The parameters of the REIMS system were optimized by single factor experiment, including the output power 20 W, cutting power 1 mm/s, and auxiliary solvent flow rate 100 μL/min, under which a stable and reliable mass spectrogram was obtained. The PCA and OPLS analysis were carried out, and there were 10 important characteristic ions were obtained (VIP>1). Among the featured ions, PE (O-16∶1/22∶6) was detected only in raw material with proportion 4.61%, whereas not detected in the fried sample. In addition, PE (22∶5/22∶6) as the highest unsaturation of the 10 phospholipid ions, the relative content of which decreased with the increase of the frying temperature, also seen in the PA (18∶1/22∶6) and PI (18∶0/22∶6), indicating that the saturation of phospholipids grew with increasing frying temperature. The method validation showed that the signal to noise ratio of selected ions was from 49.58 to 205.30 and the relative standard deviation of intra-day and inter-day accuracy was 3.10%-7.28%. REIMS is sensitive and accurate, so that it has great potential to be a simple, efficient, and accurate novel technical mean in the process of lipidomics research.

     

/

返回文章
返回