直接进样-超高效液相色谱-串联质谱法同时测定水中14种有机污染物

Simultaneous Determination of 14 Organic Pollutants in Water by Direct Injection-Ultra High Performance Liquid Chromatography Tandem Mass Spectrometry

  • 摘要: 建立了直接进样-超高效液相色谱-串联质谱(UPLC-MS/MS)法同时测定水中丙烯酰胺、灭草松、2,4滴、乐果、苦味酸、联苯胺、五氯酚、呋喃丹、甲萘威、阿特拉津、内吸磷、马拉硫磷、对硫磷和毒死蜱等14种有机污染物。水样过022 μm微孔滤膜后,以乙腈乙酸铵为流动相进行梯度洗脱,流速03 mL/min,柱温40 ℃,采用电喷雾正、负离子模式电离,动态多反应监测模式(DMRM)检测,并加入14种同位素内标,经内标法校正定量分析目标物。结果表明,14种化合物在较宽的质量浓度范围内均呈现良好的线性关系(R2≥0999 0),方法检出限和定量限分别为001~005、005~010 μg/L,不同水体3个添加水平下的平均加标回收率为779%~114%,精密度(RSD)为02%~141%(n=6)。该方法操作简单、灵敏度高,适用于地表水、地下水、生活饮用水中14种有机污染物的同时快速检测。

     

    Abstract: There are many types of organic pollutants in water, which exert great threat to human health. Developing highly efficient and precise quantification method for their detections is very important. The acrylamide, bentazone, 2,4D, dimethoate, picric acid, benzidine, pentachlorophenol, carbofuran, carbaryl, atrazine, demeton, malathion, parathion and chlorpyrifos are 14 types of important organic pollutants, which are highly harmful to human body and thereby are included in importantqualitycontrol indicators of current standard regulations, such as Environmental Quality Standards for Surface Water (GB3838—2002), Standards for Drinking Water Quality (GB5749—2006) and Quality Standard for Ground Water (GB/T14848—2017) in China. According to the specified examination methods of these standards, they commonly need enrichment of large volume of water samples before the further analysis. However, there are many drawbacks for such pretreatment: 1) The process is lengthy. 2) It can exhaust large amounts of reagents. 3) Sometimes it can produce false positive results. 4) What is even worse is being harmful for the experimenter′s health. Liquid chromatographytandem mass spectrometry is a qualitative and quantitative analysis method with high sensitivity, good selectivity and fast analysis speed, which is becoming more and more popular for the determination of trace level of organic pollutants. The direct injection method based on liquid chromatographytandem mass spectrometry has been applied in some organic pollutants examinations. However, there are still no reports on simultaneous determination of these 14 organic pollutants using direct injection method. In this study, a method of direct injectionultra high performance liquid chromatographytandem mass spectrometry (UPLCMS/MS) was developed for simultaneously determination of these 14 organic pollutants. Additionally, the dynamic multiple reaction monitoring (DMRM) mode was applied in UPLCMS/MS, which could dynamically allocate the retention time window of each target compound, significantly adjust the loading cycle time of multiple compounds and improve the analysis efficiency. Specifically, the water samples were filtered through 022 μm of microfiltration membrane and gradient eluted with ammonium acetate and acetonitrile. The flow rate was 03 mL/min and the column temperature was 40 ℃. The samples were detected by DMRM mode using positive and negative electrospray ionization (ESI±), and the 14 isotope internal standards were used for quantification by internal standard method. The calibration curves of the organic pollutants showed good linearity with the correlation coefficients (R2) over 0999 0. The limit of detection was 001005 μg/L, and the limit of quantitative was 005010 μg/L. The average recoveries at three spiked levels were 779%114% in different environmental water samples, and the RSD ranged from 02% to 141% (n=6). This method is simple, rapid, and high sensitivity, which is suitable for detection of 14 organic pollutants in the surface, underground and drinking water.

     

/

返回文章
返回