  • 摘要: 本文通过测定白血病病人血中铜的同位素丰度比,建立一套测试方法作为稳定铜同位素在生物体和示踪技术中的检测手段。在测人体血中铜时,精度好于±0.5%。

     

    Abstract: This paper describes the measurement of isotopic abundance ratio ofcopper in leukemia blood and, for comparison, the normal blood and natural copper sample have also been measured. Silicon gel-H_3PO_4 was used asstabilizer to get higher sensitivity and more stable ion current. It is provedthat organic impurities in blood sample interfere the measurement of copperseriously. To obtain better precision baking the samples made from blood isnecessary. The results show that isotopic compositions of copper in leukemiablood are the same as those in normal blood and in natural copper sample.The precision is better than ±0.5% for blood measurement.

     

/