四极质谱计中电场分布与电极的关系

The Relation between the Electric Field Distribution and the Electrode in Quadrupole Mass Spectrometer

  • 摘要: 在四极质谱计中,四极电场的电位分布与仪器的性能密切相关。理想的电位分布是双曲线等位场(本文讨论的是电极之间电位分布的问题,电极形状用其截面外形的相应曲线代表),由于双曲线形状难于加工,许多仪器采用圆电极。为了了解影响电位分布的主要因素,以便指导对电极的加工,本文不仅讨论了截面分别为双曲线和圆电极之间的差异,而且讨论了另外两种结构,它们是一段圆弧加两段切线与一段双曲线加两段切线组成的电极所形成的四极场。计算结果得出结论:四极电场的电位分布主要取决于电极截面曲线上的中心部位一小段区域的几何形状。 在计算圆截面电极的四极电场时,考虑了不同半径屏蔽罩对电场的影响。当屏蔽半径与四极场半径之比大于3.54时,屏蔽罩半径的变化对四极电场的电位分布影响不大。 本文还分析了电极的位置误差和电极截面尺寸误差对电场的影响。电极的位置误差比几何尺寸误差对四极场的影响要大得多。另外,它们对电位分布的影响与误差量的正负无关。

     

    Abstract: The performance of a Quadrupole Mass Spectrometer is affected closely by its quadrupole field. The ideal field should be a hyperbolic field. In fact, the round electrodes have been used in many instrument, because making a electrode with a hyperbolic cross section is very difficult. In the paper, besides the difference between both cases has been studied, the other shape electrode structure has been analyzed to look for the cause which affect the distribution of the electronic potential for instructing the manufacture of the electrode poles. These electrodes are the circle arctangent pole and the hyperbolic-tangent pole with some of different tangent slopes. The conclusion is that the distribution of a field is determined by the electrode figure in the center part against the field.The effects of the circle shield with zero potential has been considered. If the rate between the radius of the shield electrode and the radius of the quadrupole field is larger than 3.54, the variation of the field is very little with the radius.The influence from both errors of electrode figure and position are calculated in the paper. The effect of the position error is more than that of the figure error. In addition, the effects of the positive and the negetive of the errors is approximate equal.

     

/

返回文章
返回