避开钐干扰的钕同位素质谱分析
A Mass Spectrometric Analysis of Nd Isotope Avoiding the Interference from Sm
-
摘要: 本文讨论避开钐(Sm)干扰的钕(Nd)同位素测量程序及~(143)Nd/~(144)Nd正规化比值和~(144)Nd/含量的计算,给出了按本方法获得的钕参考标准试样的测量结果,还讨论了与钕同位素稀释分析有关的测量数据的误差传递。Abstract: The measurement procedure of Nd isotopic analysis avoiding the interference from Sm and the Calculating formulas of (~143)Nd╱~(144)Nd nornalized ratio and (~144)Nd content are described in this paper. For Nd reference standard sample, the measurement results and their error propagation are also discussed.