利用多接收器电感耦合等离子体质谱法精确测定天然岩石样品中的铼含量

李 杰, 梁细荣, 董彦辉, 涂湘林, 许继峰

李 杰, 梁细荣, 董彦辉, 涂湘林, 许继峰. 利用多接收器电感耦合等离子体质谱法精确测定天然岩石样品中的铼含量[J]. 质谱学报, 2008, 29(5): 283-289.
引用本文: 李 杰, 梁细荣, 董彦辉, 涂湘林, 许继峰. 利用多接收器电感耦合等离子体质谱法精确测定天然岩石样品中的铼含量[J]. 质谱学报, 2008, 29(5): 283-289.
LI Jie, LIANG Xi-rong, DONG Yan-hui, TU Xiang-lin, XU Ji-feng. Precise Measurement Re Concentration of Natural Rock Sample by MC-ICPMS Using Iridium to Correct for Mass Fractionation[J]. Journal of Chinese Mass Spectrometry Society, 2008, 29(5): 283-289.
Citation: LI Jie, LIANG Xi-rong, DONG Yan-hui, TU Xiang-lin, XU Ji-feng. Precise Measurement Re Concentration of Natural Rock Sample by MC-ICPMS Using Iridium to Correct for Mass Fractionation[J]. Journal of Chinese Mass Spectrometry Society, 2008, 29(5): 283-289.

利用多接收器电感耦合等离子体质谱法精确测定天然岩石样品中的铼含量

详细信息
    通讯作者:

    李 杰

  • 中图分类号: O 657.63

Precise Measurement Re Concentration of Natural Rock Sample by MC-ICPMS Using Iridium to Correct for Mass Fractionation

More Information
    Corresponding author:

    LI Jie

  • 摘要: 利用多接收器电感耦合等离子体质谱(MC-ICPMS)精确测定了天然岩石样品的铼含量。在膜除溶雾化进样条件下,铼测试样品中加入铱标准溶液,通过在线监控铱同位素的质量分馏行为来校正铼同位素的质量分馏。实验发现,铼和铱的质量分馏系数(fRefIr)是不相等的,如果认为 fRe=fIr,将会导致187Re/185Re同位素比值偏低,但是 fRe/fIr比值固定不变,这样可以通过已知的 fIr 计算出 fRe,从而得到准确的187Re/185Re同位素比值。本工作利用这种经验的质量分馏校正方法,精确的测定出天然铼标准样品的187Re/185Re同位素比值为1.674 3±0.000 1(2σ, n=25),该结果与国际纯粹与应用化学委员会(IUPAC)推荐值(1.674 0±0.001 1)以及与N-TIMS测定值(1.675 ±0.001 4)在误差范围内一致。而且,采用该经验的质量分馏校正方法测得的天然铼标准样品的187Re/185Re同位素比值与采用 fRe=fIr 校正结果相比,准确度和外部重现性都明显提高。最后采用该方法准确测定出了天然岩石中Re含量,该结果与N-TIMS测定结果吻合。
    Abstract: This study reported a measurement method of high-precision rhenium isotope ratio, 187Re/185Re, and Re concentration of natural rock samples were measured by multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS) through measuring the amount of fractionation on admixed lridium. It recognizes that the mass fractionation of MC-ICPMS appears to follow the exponential law, and the fractionation coefficients of Re and Ir are not identical, but the ratio of fRe/fIr is constant during an analytical session. Thus, this constant ratio can be used to calculate the value of fRe according to known value fIr. Replicate analyses of both Re natural standard and 185Re enriched spike determined by MC-ICPMS are consistent with those measured by negative thermal ionization mass spectrometry (N-TIMS). 187Re/185Re ratios of the Re natural standard is 1.674 3±0.000 1(2σ, n=25). The value is indistinguishable within analytical uncertainty from the value adopted by IUPAC (1.674 0±0.001 1), and is also in agreement with those measured by N-TIMS (1 675 5±0.001 4) . In addition, the precise and accurate are improved by using this empirical correction technique. The Re concentration of the natural rock samples are reasonable agree with those measured by N-TIMS.
  • [1] SHEN J J, PAPANASTASSIOU D A, WASSERBUR G J. Precise Re-Os determinations and systematics of iron meteorites[J]. Geochimica et Cosmochimica Acta,1996,60:2 887-2 900.
    [2] SMOLIAR M I, WALKER R J, MORGAN J W. Re-Os ages of group IIA, IIIA, IVA, and IVB iron meteorites[J]. Science,1996,271:1 099-1 102.
    [3] VOLKENING J, WALCZYK T, HEUMANN K. Osmium isotope ratio determinations by negative thermal ion mass spectrometry[J]. International Journal of Mass Spectrometry and Ion Physics,1991,105:147-159.
    [4] CREASER R A, PAPANASTASSIOU D A, WASSERBURG G J. Negative thermal ion mass spectrometry of osmium, rhenium and iridium [J]. Geochim Cosmochim Acta,1991,55:397-401.
    [5] HEUMANN K G, EISENHUT S, GALLUS S, et al. Recent developments in thermal ionization mass spectrometric techniques for isotope analysis: a review [J].The Analyst, 1995,120:1 291-1 300.
    [6] HASSLER D R, PEUCKER-EHRENBRINK B, RAVIZZA G E. Rapid determination of Os isotopic composition by sparging OsO4 into a magnetic-sector ICP-MS[J]. Chemical Geology, 2000,166:1-14.
    [7] 李 杰,许继峰,梁细荣. Re-Os同位素分析测试进展[J].质谱学报,2005,26(3):175-182.
    [8] SCHOENBERG R, NAGLER T F, KRAMERS J D. Precise Os isotope ratio and Re-Os isotope dilution measurements down to the picogram level using multicollector inductively coupled plasma mass spectrometry[J]. International Journal of Mass Spectrometry, 2000,197:85-94.
    [9] 李 杰,梁细荣,董彦辉,等.利用多接收器电感耦合等离子体质谱(MC-ICPMS)测定镁铁-超镁铁质岩石中的铼-锇同位素组成[J].地球化学,2007,36:153-160.
    [10] REHKAMPER M, HALLIDAY A N . Accuracy and long-term reproducibility of lead isotopic measurements by multiple-collector inductively coupled plasma mass spectrometry using an external method for correction of mass discrimination[J]. International Journal of Mass Spectrometry,1998, 181:123-133.
    [11] WALCZYK T, HEUMANN K G. Iridium isotope ratio measurements by negative thermal ionization mass spectrometry[J]. Int J Mass Spectrom Ion Proc,1993,123:139-147.
    [12] 梁细荣, 韦刚健, 李献华,等.利用MC-ICPMS精确测定143Nd/144Nd和Sm/Nd比值[J]. 地球化学,2003, 32:91-96.
    [13] SHIREY S B, WALKER R J. Carius tube digestion for low-blank rheniumosmium analysis[J]. Anal Chem,1995,67:2 136-2 141.
    [14] RUSSELL W A, PAPANASTASSIOU D A,TOMBRELLO T A. Ca isotope fractionation on the earth and other solar system material[J]. Geochim Cosmochim Acta, 1978,42:1 075-1 090.
    [15] 梁细荣, 李 杰, 漆 亮,等. 多接收器等离子体质谱精确测定铼含量及其同位素丰度[J]. 岩矿测试, 2005,24:1-6.
    [16] ROSMAN K J R, TAYLOR P D P. Isotopic compositions of the element 1997[J]. Pure Appl Chem,1998,70: 217-238.
    [17] SUZUKI K, MIYATA Y, KANAZAWA N. Precise Re isotope ratio measurements by negative thermal ion mass spectrometry (NTI-MS) using total evaporation technique[J]. Int J Mass Spectrom,2004,235:97-101.
    [18] MARECHALl C N, TELOUK P, ALBAREDE F. Precise analysis of copper and zinc isotopic compositions by plasma-source mass spectrometry[J]. Chemical Geology,1999,156:251-273.
    [19] SUZUKI K, HONDA M. Analytical method of osmium and rhenium isotopes[J]. Frontire Research on Earth Evolution, 2003.
    [20] GANGOPADHYAY A, SPROULE R A, WALKER R J, et al. Re-Os systematics of komatiites and komatiitic basalts at Dundonald Beach, Ontario, Canada: evidence for a complex alteration history and implications of a late-Archean chondritic mantle source[J]. Geochimica et Cosmochimica Acta,2005,69:5 087-5 098.
计量
  • 文章访问数:  2235
  • HTML全文浏览量:  0
  • PDF下载量:  1742
  • 被引次数: 0
出版历程
  • 收稿日期:  2007-11-19
  • 修回日期:  2008-03-24
  • 刊出日期:  2008-09-19