VG-354质谱仪磁流部件DAC故障诊断及措施

  • 摘要: 本文介绍了对VG-354质谱仪磁流部件DAC出现的故障所进行的诊断,同时针对故障现象建立了一种改变加速电压的测量方法,解决了因DAC出故障而使U、Pb等同位素无法测量的问题

     

    Abstract: The Problem Discrimination and Resolving of the VG-354 Mass Spectrometer Magnet Part DACLir Haichen; Tu Xianglin (Institute of Guangzhou Geological New Technology, Chinese Academy of Sciences, Guangzhou 510640, China )Abstract:The problem discrimination of the VG354 MS magnet part DAC was introduced,and also a new measureing method through varing accelerating voltage with special for the DAC was devoloped which soloved the measuring diffculties of some isotopes such as U and Pb because of the DAC trouble.Keywords: magnet part, trouble, discrimination, measure

     

/

返回文章
返回