Citation: | WANG Xue-zhi, SUN Jian, YANG Zhe, LI Gang, SU Hai-bo, TAN Guo-bin, GAO Wei. Design of a Miniature Space Isotope Mass Spectrometer[J]. Journal of Chinese Mass Spectrometry Society, 2023, 44(3): 357-366. DOI: 10.7538/zpxb.2022.0119 |
[1] |
ALTWEGG K, BALSIGER H, BERTHELIER J J, BIELER A, CALMONTE U, de KEYSER J, FIETHE B, FUSELIER S A, GASC S, GOMBOSI T I, OWEN T, LE ROY L, RUBIN M, SMON T, TZOU C Y. D2O and HDS in the coma of 67P/churyumov-gerasimenko[J]. Phil Trans R Soc A, 2017, 375(2 097): 2-4.
|
[2] |
HALLIS L J, HUSS G R, NAGASHIMA K, TAYLOR G J, HALLD-RSSON S A, HILTON D R, MOTTL M J, MEECH K J. Evidence for primordial water in Earth’s deep mantle[J]. Science, 2015, 350: 795-797.
|
[3] |
ALTWEGG K, BALSIGER H, BAR-NUN A, BERTHELIER J J, BIELER A, BOCHSLER P, BRIOIS C, CALMONTE U, COMBI M, de KEYSER J, EBERHARDT P, FIETHE B, FUSELIER S, GASC S, GOMBOSI T I, HANSEN K C, HASSIG M, JACKEL A, KOPP E, KORTH A, LEROY L, MALL U, MARTY B, MOUSIS O, NEEFS E, OWEN T, REME H, RUBIN M, SEMON T, TZOU C Y, WAITE H, WURZ P. 67P/churyumov-gerasimenko, a jupiter family comet with a high D/H ratio[J]. Science, 2015, 347: 3-7.
|
[4] |
LI H F, OGANOV A R, CUI H, ZHOU X F, DONG X, WANG H T. Ultrahigh-pressure magnesium hydrosilicates as reservoirs of water in early earth[J]. Phys Rev Lett, 2022, 128: 035 703.
|
[5] |
李雪松,张子斌,韦冠一,张海涛,翟利华. 四极质谱计测量天然水平氘氢丰度比[J]. 同位素,2007,20(3):129-134.
LI Xuesong, ZHANG Zibin, WEI Guanyi, ZHANG Haitao, ZHAI Lihua. Measurement of natural level ratio of D and H by quadrupole mass spectrometer[J]. Journal of Isotopes, 2007, 20(3): 129-134(in Chinese). |
[6] |
YANG Z, REN Z, CHENG Y, SUN W, XI Z, JIA W, LI G, WANG Y, GUO M, LI D. Review and prospect on portable mass spectrometer for recent applications[J]. Vacuum, 2022, 199: 110 889.
|
[7] |
张兆清,赵雅平,王志强,刘权卫,侯留东. 磁质谱的发展及应用进展[J]. 化学分析计量,2022,31(2):94-100.
ZHANG Zhaoqing, ZHAO Yaping, WANG Zhiqiang, LIU Quanwei, HOU Liudong. Development and application of magnetic mass spectrometry[J]. Chemical Analysis and Meterage, 2022, 31(2): 94-100(in Chinese). |
[8] |
REN Z, GUO M, CHENG Y, WANG Y, SUN W, ZHANG H, DONG M, LI G. A review of the development and application of space miniature mass spectrometers[J]. Vacuum, 2018, 155: 108-117.
|
[9] |
SNYDER D T, PULLIAM C J, OUYANG Z, GRAHAM R. Miniature and fieldable mass spectrometers: recent advances[J]. Analytical Chemistry, 2016, 88(1): 2-29.
|
[10] |
HOFFMAN J H, HANSON W B, LIPPINCOTT C R. The magnetic ion-mass spectrometer on atmosphere explorer[J]. Radio Science, 1973, 8(4): 315-322.
|
[11] |
HOFFMAN J H, HODGES R, WRIGHT W W, BLEVINS V A, BROOKS L D. Pioneer venus sounder probe neutral gas mass spectrometer[J]. IEEE Transactions on Geoscience & Remote Sensing, 1980, GE-18(1): 80-84.
|
[12] |
BALSIGER H, ALTWEGG K, BOCHSLER P, EBERHARDT P, FISCHER J, GRAF S, JÄCKEL A, KOPP E, LANGER U, MILDNER M, MÜLLER J, RIESEN T, RUBIN M, SCHERER S, WURZ P, WÜTHRICH S, ARIJS E, DELANOYE S, KEYSER J D, NEEFS E, NEVEJANS D, RÈME H, AOUSTIN C, MAZELLE C, MÉDALE J L, SAUVAUD J A, BERTHELIER J J, BERTAUX J L, DUVET L, ILLIANO J M, FUSELIER S A, GHIELMETTI A G, MAGONCELLI T, SHELLEY E G, KORTH A, HEERLEIN K, LAUCHE H, LIVI S, LOOSE A, MALL U, WILKEN B, GLIEM F, FIETHE B, GOMBOSI T I, BLOCK B, CARIGNAN G R, FISK L A, WAITE J H, YOUNG D T, WOLLNIK H. Rosinarosetta orbiter spectrometer for ion and neutral analysis[J]. Space Sci Rev, 1998, 21(11): 1527-1535.
|
[13] |
HÄSSIG M, ALTWEGG K, BERTHELIER J J, CALMONTE U, de KEYSER J, FIETHE B, FUSELIER S A, GOMBOSI T, le ROY L, OWEN T, RUBIN M. The capabilities of ROSINA/DFMS to measure argon isotopes at comet 67P/churyumov-gerasimenko[J]. Planetary and Space Science, 2015, 105: 175-178.
|
[14] |
COMBI M, SHOU Y, FOUGERE N, TENISHEV V, ALTWEGG K, RUBIN M, BOCKELÉE-MORVAN D, CAPACCIONI F, CHENG Y C, FINK U. The surface distributions of the production of the major volatile species, H2O, CO2, CO and O2, from the nucleus of comet 67P/churyumov-gerasimenko throughout the rosetta mission as measured by the ROSINA double focusing mass spectrometer[J]. Icarus: International Journal of Solar System Studies, 2020, 335: 2-14.
|
[15] |
HOFFMAN J, CHANEY R, HAMMACK H. Phoenix mars missionthe thermal evolved gas analyzer[J]. Journal of the American Society for Mass Spectrometry, 2008, 19: 1377-1383.
|
[16] |
AGUILAR M, ALI CAVASONZA L, AMBROSI G, ARRUDA L, ATTIG N, BARAO F, BARRIN L, BARTOLONI A, BA瘙塁EGˇMEZ-DU PREE S, BATES J, BATTISTON R, BEHLMANN M, BEISCHER B, BERDUGO J, BERTUCCI B, BINDI V, de BOER W, BOLLWEG K, BORGIA B, BOSCHINI M J, BOURQUIN M, BUENO E F, BURGER J, BURGER W J, BURMEISTER S, CAI X D, CAPELL M, CASAUS J, CASTELLINI G, CERVELLI F, CHANG Y H, CHEN G M, CHEN H S, CHEN Y, CHENG L, CHOU H Y, CHOURIDOU S, CHOUTKO V, CHUNG C H, CLARK C, COIGNET G, CONSOLANDI C, CONTIN A, CORTI C, CUI Z, DADZIE K, DAI Y M, DELGADO C, DELLA TORRE S, DEMIRKZ M B, DEROME L, di FALCO S, di FELICE V, DAZ C, DIMICCOLI F, von DOETINCHEM P, DONG F, DONNINI F, DURANTI M, EGOROV A, ELINE A, FENG J, FIANDRINI E, FISHER P, FORMATO V, FREEMAN C, GALAKTIONOV Y, GÁMEZ C, GARCALPEZ R J, GARGIULO C, GAST H, GEBAUER I, GERVASI M, GIOVACCHINI F, GMEZCORAL D M, GONG J, GOY C, GRABSKI V, GRANDI D, GRAZIANI M, GUO K H, HAINO S, HAN K C, HASHMANI R K, HE Z H, HEBER B, HSIEH T H, HU J Y, HUANG Z C, HUNGERFORD W, INCAGLI M, JANG W Y, JIA Y, JINCHI H, KANISHEV K, KHIALI B, KIM G N, KIRN T, KONYUSHIKHIN M, KOUNINA O, KOUNINE A, KOUTSENKO V, KUHLMAN A, KULEMZIN A, la VACCA G, LAUDI E, LAURENTI G, LAZZIZZERA I, LEBEDEV A, LEE H T, LEE S C, LELUC C, LI J Q, LI M, LI Q, LI S, LI T X, LI Z H, LIGHT C, LIN C H, LIPPERT T, LIU Z, LU S Q, LU Y S, LUEBELSMEYER K, LUO J Z, LYU S S, MACHATE F, MA C, MARN J, MARQUARDT J, MARTIN T, MARTNEZ G, MASI N, MAURIN D, MENCHACAROCHA A, MENG Q, MO D C, MOLERO M, MOTT P, MUSSOLIN L, NI J Q, NIKONOV N, NOZZOLI F, OLIVA A, ORCINHA M, PALERMO M, PALMONARI F, PANICCIA M, PASHNIN A, PAULUZZI M, PENSOTTI S, PHAN H D, PLYASKIN V, POHL M, PORTER S, QI X M, QIN X, QU Z Y, QUADRANI L, RANCOITA P G, RAPIN D, REINA CONDE A, ROSIERLEES S, ROZHKOV A, ROZZA D, SAGDEEV R, SCHAEL S, SCHMIDT S M, von DRATZIG A S, SCHWERING G, SEO E S, SHAN B S, SHI J Y, SIEDENBURG T, SOLANO C, SONG J W, SONNABEND R, SUN Q, SUN Z T, TACCONI M, TANG X W, TANG Z C, TIAN J, TING S C C, TING S M, TOMASSETTI N, TORSTI J, TÜYSÜZ C, URBAN T, USOSKIN I, VAGELLI V, VAINIO R, VALENTE E, VALTONEN E, VZQUEZ ACOSTA M, VECCHI M, VELASCO M, VIALLE J P, WANG L Q, WANG N H, WANG Q L, WANG S, WANG X, WANG Z X, WEI J, WENG Z L, WU H, XIONG R Q, XU W, YAN Q, YANG Y, YI H, YU Y J, YU Z Q, ZANNONI M, ZHANG C, ZHANG F, ZHANG F Z, ZHANG J H, ZHANG Z, ZHAO F, ZHENG Z M, ZHUANG H L, ZHUKOV V, ZICHICHI A, ZIMMERMANN N, ZUCCON P. The alpha magnetic spectrometer (AMS) on the international space station: part Ⅱresults from the first seven years[J]. Physics Reports, 2021, 894: 1116.
|
[17] |
HADJAR O, SCHLATHÖLTER T, DAVILA S, CATLEDGE S A, KUHN K, KASSAN S, KIBELKA G, CAMERON C, VERBECK G F. IonCCD detector for miniature sector-field mass spectrometer: investigation of peak shape and detector surface artifacts induced by keV ion detection[J]. J Am Soc Mass Spectrom, 2011, 22: 1872-1884.
|
[18] |
DONG M, CHENG Y J, SUN W J, GUO M R, GANG L I, YA L I, HAN X D. Performance study of miniature magnetic sector mass spectrometer[J]. Journal of Astronautic Metrology and Measurement, 2018,38(4): 28-31.
|
[19] |
邹盛强,翟利华,林跃武. 磁电双聚焦质量分析系统的研制[J]. 现代应用物理,2018,9(1):62-67.
ZOU Shengqiang, ZHAI Lihua, LIN Yuewu. Development of magnetic-electric double focusing mass analyzer[J]. Modern Applied Physics, 2018, 9(1): 62-67(in Chinese). |
[20] |
张礼朋,董猛,成永军,吴海燕,钱洁,张曙光,张英军,葛赛金,李晓旭. 小型化磁质谱仪离子源的模拟及优化设计[J]. 真空,2019,56(2):51-56.
ZHANG Lipeng, DONG Meng, CHENG Yongjun, WU Haiyan, QIAN Jie, ZHANG Shuguang, ZHANG Yingjun, GE Saijin, LI Xiaoxu. Simulation and optimization of electron impact ion source for miniaturized magnetic mass spectrometer[J]. Vacuum, 2019, 56(2): 51-56(in Chinese). |
[21] |
赵以德,马亚芳,李泰国,郭美如,肖玉华. 小型磁偏转质谱计离子源设计与验证[J]. 真空,2015,52(2):41-43.
ZHAO Yide, MA Yafang, LI Taiguo, GUO Meiru, XIAO Yuhua. An ion source for a miniature magnetic sector mass spectrometer[J]. Vacuum, 2015,52(2):41-43(in Chinese). |
[1] | JIANG Zong-yao, PAN Xin-yuan, JIA Bin, XU Guo-bin, ZHOU Zhen, YANG Peng-yuan. Development of a Novel Electron Source Linear Ion Trap/Time-of-Flight Hybrid Tandem Mass Spectrometer[J]. Journal of Chinese Mass Spectrometry Society, 2013, 34(4): 193-201. DOI: 10.7538/zpxb.2013.34.04.0193 |
[2] | YANG Xiao-bing, DING Song-tao, WANG An-bang. Electron Ionization Mass Spectrum Research on Tert-Butylhydroquinone[J]. Journal of Chinese Mass Spectrometry Society, 2011, 32(5): 278-282. |
[3] | HUANG Chao, ZHAO Xue-hong, ZHANG Jian-chao, WANG Yan. Influence of the Space Charge in Electron Impact Ion Source on Its Performance[J]. Journal of Chinese Mass Spectrometry Society, 2011, 32(2): 71-76. |
[4] | GAO Wei, HUANG Zheng-xu, GUO Chang-juan, NIAN Hui-qing, DONG Jun-guo, FU Zhong, CHEN Shao-de, ZHOU Zhen. Electron Ionization and Orthogonal Acceleration Time-of-Flight Mass Spectrometer[J]. Journal of Chinese Mass Spectrometry Society, 2008, 29(4): 209-212. |
[5] | DAI Hai-xue, XU Yan-xia, LIU Yun, LI Xiao-rong, XUE Ming. Analysis of Cryptotanshinone by Electron Spray Ionization Mass Spectrometry and Electron Ionization Mass Spectrometry[J]. Journal of Chinese Mass Spectrometry Society, 2006, 27(4): 198-202. |
[6] | HAN Hai. Determination of Piperazinylethylestrone by Electron Ionization Mass Spectrometry and Fast-atom Bombardment Mass Spectrometry[J]. Journal of Chinese Mass Spectrometry Society, 2006, 27(1): 30-32. |
[7] | XU Yan-xia, KOU Yu-ying, XUE Ming, RUAN Jin-xiu, ZHANG Zhen-qing, LIU Ke-liang. Analysis of Phencynonate by Electron Ionization Mass Spectrometry and Electron Spray Ionization Mass Spectrometry[J]. Journal of Chinese Mass Spectrometry Society, 2006, 27(1): 22-25. |
[8] | Study on Realoxifen Hydrochloride by Electron Ionization Mass Spectrometry and Fast-atom Bombardment Mass Spectrometry[J]. Journal of Chinese Mass Spectrometry Society, 2004, 25(2): 107-107. |
[9] | STUDY ON BIS-PIPERAZINIUM SALTS(M~(2+) 2Br~- 2HCl) BY ELECTRON IMPACT IONIZATION MASS SPECTROMETRY[J]. Journal of Chinese Mass Spectrometry Society, 2003, 24(3): 408-408. |
[10] | The studies of Electron Impact Mass Spectra of Some Sugar Orthoesters[J]. Journal of Chinese Mass Spectrometry Society, 1997, 18(4): 11-11. |
1. |
谢新侃. 质谱仪在化工企业周围环境分析中的应用研究. 天津化工. 2024(01): 16-18 .
![]() |